Ei Package Sets

CONFIGURATION

Single or multiple pump package sets, horizontal end suction close and long coupled, split case long coupled, multi-stage multi-outlet and vertical turbine all electric motor or engine driven

DISCHARGE & PERFORMANCE
• End Suction (Single Stage) – 32 mm to 150 mm. Outputs up to 500 m3 /h Heads up to 15.2 bar
• Outputs up to 230 l/s Heads up to 60 bar
• Split Case – 80 mm to 300 mm. Heads up to 44.5 bar (Approved fire set)
• Multi-stage multi-outlet – 100 mm to 125 mm. Outputs up to 315 l/s. Heads up to 60 bar
• Vertical Turbine – 200 mm to 508 mm Outputs up to 9000 m3 /h
• Multi-stage / multi-outlet – 50 mm to 250 mm. Outputs up to 850 m3/h.
Heads up to 850 m. Up to 140 oC

FEATURES
• Meeting the requirements of worldwide insurance and approvals bodies
• End Suction – Centreline discharge back pull-out rotating element can be removed without disturbing pipe work
• End Suction – Close coupled, space and cost saving solution
• Axially split case rotating element can be removed without disturbing pipework
• Rigid, box-section baseplates for end suction and split case long coupled packages
• Stainless steel shaft with tight tolerances designed to transmit the maximum load across full pump curve
• Bearing arrangements of ample proportion
• IE2 motors fitted as standard
• Impellers machined and hand finished to meet customer duty